The alarm can be silenced while you fix the issue, but a red light will stay on until the issue is solved. SepticTankParts.com is an independent seller of replacement septic system parts for numerous original manufacturers and the use of the names of the original manufacturers, their models, types, part number and other descriptive product information is only for the purpose of aiding customers in cross-referencing the appropriate SepticTankParts.com part. Please note that the performance will be different depending on the frequency applied, so refer to the performance curves for information on each. Inspections | The kit includes: two diaphragm blocks, two diaphragm heads. Please be sure to disconnect power from the unit before completing repairs. Please email or call for your closest or most convenient option. Quick delivery, product as described in original box and packaging. Insert the actuating rod in accordance with the gap of the frame. That depends on the application. 714 W. Elnora St., Odon, Indiana 47562 Over time, some internal parts may wear out. Stop tightening when this happens. Secure the upper housing with the bolts that were removed in STEP 1. This ensures your product can have a long life. It also has thermal protection and over-pressurization protection. HIBLOW HP-60/80 Rebuild/Repair Kit -Genuine Factory Certified Free Fast Shipping. Replacement gasket for Hiblow models HP60 & HP80. The quiet septic air pumps operate with low power consumption and have an extremely long lifespan. Submersible Pumps | If you bought your Hiblow HP 80 from us it is covered by a 2 year warranty. Order By Phone (800) 778-1540 or (636) 583-1608 M-F: 8:00AM to 4:30PM (CST). This gasket is located between the cover and the filter. Install the heads on both sides with the 4 screws that were removed originally. Learn How To Install A Hiblow Rebuild Kit. Grease Trap Pumping, Norweco Parts | Remove all the bolts from the four corners. Using a 7mm (1/4in) wrench or nut driver remove the U-lock nuts that hold the diaphragm to the magnetic rod block. Over time, some internal parts may wear out. Home HP Alarm Series Hiblow HP-80-013A Septic Air Pump. The Hiblow HP100 LL & HP120 LL Diaphragm Kit can be used to repair/rebuild the HP100 LL & HP120 LL models. The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. The kIt includes: two diaphragm blocks, two diaphragm heads, one replacement air filter, and hardware. Installing the HP 60 and HP 80 rebuild kit is easy and requires only a screwdriver. It comes with. Fast Ship, Just what I needed at a fair price. When your system stops working, may be able to rebuild it, instead of buying a new septic system. A cool and dry location out of the sun is ideal. a replacement filter, a replacement safety screw and hardware. Septic Pumping | Shipping was very fast! Copyright 2005-2022 Septic Tank Parts Online Store. If your pump runs and hums but does not produce air, you may just need a rebuild kit. A professional service provider may also be able to determine the HIBLOW pump model you need. Make sure to check the diffusers in your pond or wastewater system to make sure they are not excessively clogged. Find out more about cookies and how you can refuse them. Replacement base plate gasket for Hiblow models HP50W/HP60W/HP80W. M-F: 7a-5p Sat: 7a-10a Sun: closed, Rex Vault Service Site design by DesignHub. If your pump runs and hums but does not produce air, you may just need a rebuild kit. Replacement gasket for Hiblow models HP100 & HP120. The kit includes: two diaphragm blocks, two diaphragm heads, one replacement air filter, and hardware. 2022 HIBLOW USA. Using a phillips screwdriver could cause you to strip out the bolts. 807 E. Jourdan St., Newton, Illinois 62448 In addition to failing quickly, they can be noisy, and will often destroy the inside of the pump. This alarm will sound to alert you of any issues regarding your air pump. The Complete Kit includes everything you need to rebuild your Aerator. The Hiblow HP100 & HP120 Diaphragm Kit can be used to repair/rebuild the Hiblow models HP100 & HP120. This website is owned independently separate from Hiblow USA, Techno Takatsuki, LLC, 3.6 psi Max Continuous Operating Pressure. Make sure the gapes between the actuating rod and the electromagnet are even. Techno Takatsuki Co Ltd|Hiblow Europe|Hiblow Korea. During this time, it will require little maintenance. It has. Refer to the owners manual for instructions on how to reset the safety slide switch. The Hiblow HP60 & HP80 Air Filter is designed to keep dirt and particles from entering the internal pump. Fasten the screw with the nut supplied and tighten with a flathead screwdriver. The Hiblow HP60/80 (#80PC000042) rebuild kit is compatible with all of the following models: Below are instructions on how to install this repair kit in a Hiblow air pump. Reconnect the L-Tubes to the diaphragm head on each side. The warning listed above is provided to California consumers to ensure compliance with California Proposition 65. Remove the four screws that hold the chamber block and the casing block on both side (4 screws on each side). The Hiblow HP40 Diaphragm Kit can be used to repair/rebuild the Hiblow model HP40. This is done easier using a 7mm or 1/4in socket instead of a phillips screwdriver. Over time, some internal parts may wear out. The additional backpressure of clogged diffusers may be exceeding the design pressure for the pump model you are using. Draw a new safety screw through the hole in the SP switch and the holes in the L shaped lever and spring contact. Replacement base plate gasket for Hiblow models HP60 & HP80. JavaScript seems to be disabled in your browser. A trick to getting the nut on the safety screw is to use a pair of needlenose pliers to hole the nut in place while you turn the screw into it. If it is out of warranty or not purchased through TG Waste Water than a HP 60/HP 80 or HP 100/HP 120 Rebuild kit is the next best thing. Hiblow is known for providing top-of-the-line septic aerators. This kit includes 2 diaphragms with mounting blocks, 2 heads with air valves, a replacement air filter, and a replacement safety screw. TGWasteWater uses cookies to give you the best shopping experience. {"modules":["unloadOptimization","bandwidthDetection"],"unloadOptimization":{"browsers":{"Firefox":true,"Chrome":true}},"bandwidthDetection":{"url":"https://ir.ebaystatic.com/cr/v/c1/thirtysevens.jpg","maxViews":4,"imgSize":37,"expiry":300000,"timeout":250}}. Rebuilding is typically a fraction of the cost of a new system. Finally separate the diaphragm mounting block and rod. If your pump runs and hums but does not produce air, you may just need a rebuild kit. NOTE: DO NOT DISCARD SCREWS, THEY WILL BE REUSED. Aeration | NOTE: DO NOT DISCARD BOLTS, THEY WILL BE REUSED. Truly, they are known for their longevity and premium grade materials. (618) 783-2416 HIBLOW linear pumps are not dual voltage, so please check the data label on the pump and only apply the correct voltage as a power source. If you continue to use our services, we will assume that you agree to the use of such cookies. Highly recommended. Over time, some internal parts may wear out. the 17/07/2018. Your HP series air pump was likely jostled during shipping and the safety slide switch has moved to the inoperable position which deactivates the electric motor. Hook your air pump back up to your system! Drain Fields | If upper pump housingis difficult to remove due to the heavily stuck internal seal, pry it open by inserting the tip of a flat-head screwdriver into the clearance between the exhaust nozzle and upper housing. Hiblow HP-80 0119 septic air pump is a model of Hiblow that is used in specific septic systems. An inverter would be needed in order to use a HIBLOW linear pump in a system powered by DC. Don't waste your money buying a new aerator when you can fix the one you have for a fraction of the cost. The Hiblow HP-80-013A also features an oil-less contamination free design, which will keep your air pump clean and free of unwanted germs or dirt. It is recommended the filter be cleaned every six months and replaced every year. All rights reserved. While these aerators are the longest lasting on the market they do get worn out over time. - Top Rated Plus - opens in a new window or tab, - eBay Money Back Guarantee - opens in a new window or tab, - for PayPal Credit, opens in a new window or tab, Learn more about earning points with eBay Mastercard, - eBay Return policy - opens in a new tab or window, - eBay Money Back Guarantee - opens in a new tab or window. Installed rebuild kit two days ago. Please contact the manufacturer of your treatment system to ensure the correct sizing of the air pump for your specific unit. For wastewater applications, always contact your treatment system manufacturer before altering any aeration settings. Knock off kits are common on Amazon and eBay. Did you buy a knock off repair kit? In fact, Hiblow's aerators have been put to the test across the country and proven to last long lives. Septic Tank Parts|7059 Highway 47 Union, Mo 63084, Hiblow HP50/60/80 Dual Port Base Plate Gasket. The screw is designed so that the nut will turn freely when it is properly fastened. Service Agreements | Order by phone Call us toll free: (800) 778-1540 Weekdays 8:00AM to 4:30PM (CST). Hiblow HP-80 linear septic air pump aerator - 2-year warranty. They are made from inferior materials and do not fit to specification. Install the new diaphragm on the actuating rod before inserting the rod back into the pump. Use single quotes (') for phrases. Most likely the nut attaching the diaphragm to the rod was either not installed, or not tightened snug enough. Thank you. Not to mention rebuild kits are available to prolong the lifespan of your pump. Replace the sound absorber removed in STEP 2 and place the upper housing back on the body. Hiblow is one of the most popular Septic Air Pump brands on the market due to its reliability and ease of use. Controls & Alarms | The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. The gasket goes between the bottom plate and air tank keeping the bottom chamber sealed from the top so proper air flow is maintained. You can find a rebuild kit on Wholesale Septic Supply. However, after 4 to 6 years, your system may need to be rebuilt. quick delivery, product is as advertised. Filtration | For more information, go to www.P65Warnings.ca.gov. The Hiblow HP-60and HP-80 diaphragm replacement kit is the standardrebuild kitand includes the necessary components for replacing the diaphragms on your Hiblow model. In a garage, shed, or crawlspace are all good options. The HP 60 and HP 80 are diaphragm operated aerators. It has low vibration and pulsation and starting current, so you should not hear any background buzzing in your home. Pull off the white sound absorber from around the internal pumping unit and disconnect the L-TUBES on each end from the diaphragm head. Replacement base plate gasket for Hiblow models HP100 & HP120. Remove one of the diaphragms from the actuating rod and pull out the other diaphragm with the magnetic rod. No, the operating principle of our linear pumps utilize Alternating Current (AC) to shuttle the rod back and forth, and thus create pressure or vacuum. Refresh your browser window to try again. Seller assumes all responsibility for this listing. This gasket is located between the cover and filter. Copyright 1995-2022 eBay Inc. All Rights Reserved. Overall, you want to keep any additional heat to a minimum and you will have a happy pump with a long life. When the diaphragms fail, the pump will shut off and your alarm should sound. Thank you so much! ORDER ONLINE ANYTIME OR CALL OUR SALES STAFF TO PLACE AN ORDER BETWEEN 8:00 AM to 4:30 PM CT MON-FRI TOLL FREE: (877)-925-5132 MOST ORDERS PLACED BEFORE 2 PM CST WILL BE SHIPPED THE SAME DAY, 2 Diaphragm Heads with Factory Installed Air Check Valves, Hoot Troy Air H365, H450, H500, LA500, H600, 7mm or 1/4in Wrench, Socket, or Nut Driver. An electronic copy of the owners manual can be found on the Support tab of our website. As long as the system has not been rebuilt before, and isnt showing signs of rust, you can usually rebuild. The Hiblow HP-80-013A Septic Air Pump comes standard with an alarm attached. The Hiblow HP-80-013A Septic Air Pump is known for its quiet operation. Yes, all HIBLOW pumps can operate on either 50hz or 60hz. Septic Care, Rex Vault Service M-F: 7a-5p Sat: 7a-10a Sun: closed. Something went wrong. The diaphragms normally need to be replaced every 4 to 6 years depending on the application. The kit includes: two diaphragm blocks, two diaphragm heads, a replacement filter, a replacement safety screw and hardware. The typical Hiblow HP-80-013A Septic Air Pump should last 10 to 12 years. Use spaces to separate tags. For detailed instillation instructions click here. Secure the diaphragm on the other side and tighten the U-lock nut with the box driver. Septic Risers | We have numerous distributors across North America that can supply you with both pumps and repair parts. Using a phillips screwdriver. View cart for details. So far, so good.. the 08/06/2018, the 13/03/2018, the 06/01/2018, the 07/08/2017, Shaft Style Septic Aerators - Jet/Norweco Replacements, View All Control Panels & Control Panel Parts, Hiblow HP 80 Pond or Septic Air Pump UL APPROVED HP80 HP 80, SPI BIO-A Double Light Control Panel for Aerobic Septic Systems - 50B138, SPI BIO-B Double Light Control Panel for Aerobic Septic Systems - 50B006. This ensures you completely fix the problem at hand. The Hiblow HP-80-013A is UL rated for outdoor use. If it must be installed outside, it is best to ensure that the pump gets good ventilation and is not in direct sunlight. If your pump runs and hums but does not produce air, you may just need a rebuild kit. The Hiblow HP60 & HP80 Diaphragm Kit can be used to repair/rebuild the Hiblow models HP60 & HP80. (812) 636-7386 If the air pump is over 10 years old, we would recommend replacing the air pump. Use new U-lock and washer that come with the kit to prevent loosening and causing failure of the pump. Nevertheless, they have been known to power systems around the world for nearly 100 years. You must have JavaScript enabled in your browser to utilize the functionality of this website. WARNING: These products can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.

Sitemap 17